[1] “Global status report on road safety,” 2015. [Online]. Available: https://www.who.int/ violence injury prevention/road safety status/2015/en/. [2] “Car accident from drowsy driving statistics,” 2017. [Online]. Available: https: //www.nhtsa.gov/risky-driving/drowsy-driving. [3] Y. Masaki, D. Mitsuo,W. Junichi, O. Shin, T. Noriyasu, H. Tomoyuki, and M. Yasufumi, “Hand-held monitor of sympathetic nervous system using salivary amylase activity and its validation by driver fatigue assessment,” Biosensors and Bioelectronics, vol. 21, no. 7, pp. 1007–1014, 2006. [4] H. J. Baek, G. S. Chung, K. K. Kim, and K. S. Park, “A smart health monitoring chair for nonintrusive measurement of biological signals,” IEEE Transactions on Information Technology in Biomedicine, vol. 16, no. 1, pp. 150–158, 2012. [5] J. Gomez-Clapers and R. Casanella, “A fast and easy-to-use ecg acquisition and heart rate monitoring system using a wireless steering wheel,” IEEE Sensors Journal, vol. 12, no. 3, pp. 610–616, 2012. [6] J. Schneider, C. Koellner, and S. Heuer, “An approach to automotive ecg measurement validation using a car-integrated test framework,” in 2012 IEEE Intelligent Vehicles Symposium, 2012, pp. 950–955. [7] T. Blocher, J. Schneider, M. Schinle, andW. Stork, “An online ppgi approach for camera based heart rate monitoring using beat-to-beat detection,” in 2017 IEEE Sensors Applications Symposium (SAS), 2017, pp. 1–6. [8] E. Schires, P. Georgiou, and T. S. Lande, “Vital sign monitoring through the back using an uwb impulse radar with body coupled antennas,” IEEE Transactions on Biomedical Circuits and Systems, vol. 12, no. 2, pp. 292–302, 2018. [9] G. Wusk and H. Gabler, “Non-invasive detection of respiration and heart rate with a vehicle seat sensor,” Sensors, vol. 18, no. 5, p. 1463, 2018. [10] G. Balakrishnan, F. Durand, and J. Guttag, “Detecting pulse from head motions in video,” in 2013 IEEE Conference on Computer Vision and Pattern Recognition, 2013, pp. 3430–3437. [11] C. Br¨user, C. H. Antink, T. Wartzek, M. Walter, and S. Leonhardt, “Ambient and unobtrusive cardiorespiratory monitoring techniques,” IEEE Reviews in Biomedical Engineering, vol. 8, pp. 30–43, 2015. [12] H. Shin, S. Jung, J. Kim, and W. Chung, “Real time car driver’s condition monitoring system,” in SENSORS, 2010 IEEE, 2010, pp. 951–954. [13] W.-J. Lin, “A physiological information extraction method based on wearable ppg sensors with motion artifact removal,” Academic thesis, Department of Electrical Engineering, National Tsing Hua University, 2014. [14] I. Sadek, J. Biswas, and B. Abdulrazak, “Ballistocardiogram signal processing: a review,” Health information science and systems, vol. 7, no. 1, p. 10, 2019. [15] L. Giovangrandi, O. T. Inan, R. M. Wiard, M. Etemadi, and G. T. A. Kovacs, “Ballistocardiography— a method worth revisiting,” in 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2011, pp. 4279–4282. [16] E. Pinheiro, O. Postolache, and P. Gir˜ao, “Theory and developments in an unobtrusive cardiovascular system representation: ballistocardiography,” The open biomedical engineering journal, vol. 4, p. 201, 2010. [17] W. R. Scarborough, “Proposals for ballistocardiographic nomenclature and conventions: Revised and extended: Report of committee on ballistocardiographic terminology,” Circulation, vol. 14, pp. 435–450, 09 1956. [18] I. Starr, A. Rawson, H. Schroeder, and N. Joseph, “Studies on the estimation of cardiac ouptut in man, and of abnormalities in cardiac function, from the heart’s recoil and the blood’s impacts; the ballistocardiogram,” American Journal of Physiology-Legacy Content, vol. 127, no. 1, pp. 1–28, 1939. [19] W. R. SCARBOROUGH, S. A. TALBOT, J. R. BRAUNSTEIN, M. B. RAPPAPORT, W. DOCK, W. R. SCARBOROUGH, W. Hamilton, J. E. SMITH, J. L. NICKERSON, S. A. TALBOT et al., “Proposals for ballistocardiographic nomenclature and conventions: Revised and extended: Report of committee on ballistocardiographic terminology,” Circulation, vol. 14, no. 3, pp. 435–450, 1956. [20] O. T. Inan, M. Etemadi, R. M.Wiard, G. T. Kovacs, and L. Giovangrandi, “Non-invasive measurement of valsalva-induced hemodynamic changes on a bathroom scale ballistocardiograph,” in 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE, 2008, pp. 674–677. [21] J. H. Shin, K. M. Lee, and K. S. Park, “Non-constrained monitoring of systolic blood pressure on a weighing scale,” Physiological measurement, vol. 30, no. 7, p. 679, 2009. [22] R. Casanella, J. Gomez-Clapers, and R. Pallas-Areny, “On time interval measurements using bcg,” in 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE, 2012, pp. 5034–5037. [23] J. H. Shin and K. S. Park, “Hrv analysis and blood pressure monitoring on weighing scale using bcg,” in 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE, 2012, pp. 3789–3792. [24] W. R. Scarborough, “Proposals for ballistocardiographic nomenclature and conventions: Revised and extended: Report of committee on ballistocardiographic terminology,” Circulation, vol. 14, pp. 435–450, 09 1956. [25] R. Gonzalez-Landaeta, O. Casas, and R. Pallas-Areny, “Heart rate detection from an electronic weighing scale,” Physiological Measurement, vol. 29, pp. 979–88, Aug 2008. [26] T. Koivistoinen, S. Junnila, A. Varri, and T. Koobi, “A new method for measuring the ballistocardiogram using emfi sensors in a normal chair,” in The 26th annual international conference of the IEEE engineering in medicine and biology society, vol. 1. IEEE, 2004, pp. 2026–2029. [27] K. Watanabe, T. Watanabe, H. Watanabe, H. Ando, T. Ishikawa, and K. Kobayashi, “Noninvasive measurement of heartbeat, respiration, snoring and body movements of a subject in bed via a pneumatic method,” IEEE transactions on biomedical engineering, vol. 52, no. 12, pp. 2100–2107, 2005. [28] C. Br¨user, K. Stadlthanner, S. de Waele, and S. Leonhardt, “Adaptive beat-to-beat heart rate estimation in ballistocardiograms,” IEEE Transactions on Information Technology in Biomedicine, vol. 15, no. 5, pp. 778–786, 2011. [29] R. C. Gonzalez and R. E. Woods, Digital Image Processing, 4th ed. Pearson/Prentice Hall, 2018, ch. 7.10. [30] I. Sadek, J. Biswas, B. Abdulrazak, Z. Haihong, and M. Mokhtari, “Continuous and unconstrained vital signs monitoring with ballistocardiogram sensors in headrest position,” in 2017 IEEE EMBS International Conference on Biomedical Health Informatics (BHI), 2017, pp. 289–292. [31] J. Jin, X. Wang, S. Li, and Y. Wu, “A novel heart rate detection algorithm in ballistocardiogram based on wavelet transform,” in 2009 Second International Workshop on Knowledge Discovery and Data Mining, 2009, pp. 76–79. [32] L. Marple, “Computing the discrete-time ”analytic” signal via fft,” IEEE Transactions on Signal Processing, vol. 47, no. 9, pp. 2600–2603, 1999. [33] B. Y. Su, K. C. Ho, M. Skubic, and L. Rosales, “Pulse rate estimation using hydraulic bed sensor,” in 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2012, pp. 2587–2590. [34] J. H. Shin, B. H. Choi, Y. G. Lim, D. U. Jeong, and K. S. Park, “Automatic ballistocardiogram (bcg) beat detection using a template matching approach,” in 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2008, pp. 1144–1146. [35] K. Lydon, B. Y. Su, L. Rosales, M. Enayati, K. Ho, M. Rantz, and M. Skubic, “Robust heartbeat detection from in-home ballistocardiogram signals of older adults using a bed sensor,” in 2015 37th annual international conference of the IEEE engineering in medicine and biology society (EMBC). IEEE, 2015, pp. 7175–7179. [36] E. J. Pino, J. A. Ch´avez, and P. Aqueveque, “Bcg algorithm for unobtrusive heart rate monitoring,” in 2017 IEEE Healthcare Innovations and Point of Care Technologies (HIPOCT). IEEE, 2017, pp. 180–183. [37] J. Pan and W. J. Tompkins, “A real-time qrs detection algorithm,” IEEE Transactions on Biomedical Engineering, vol. BME-32, no. 3, pp. 230–236, 1985. [38] A. K. Jain, “Data clustering: 50 years beyond k-means,” Pattern recognition letters, vol. 31, no. 8, pp. 651–666, 2010. [39] S. V. Vaseghi, Advanced Digital Signal Processing and Noise Reduction, 4th ed. John- Wiley Sons Ltd., 2008, ch. 10.4. [40] A. V. Oppenheim and R. W. Schafer, Discrete-Time Signal Processing, 3rd ed. Pearson/ Prentice Hall., 2010, ch. 7.5.1. [41] S. Boll, “Suppression of acoustic noise in speech using spectral subtraction,” IEEE Transactions on acoustics, speech, and signal processing, vol. 27, no. 2, pp. 113–120, 1979. [42] J. Rosenberg, A. Amjad, P. Breeze, D. Brillinger, and D. Halliday, “The fourier approach to the identification of functional coupling between neuronal spike trains,” Progress in biophysics and molecular biology, vol. 53, no. 1, pp. 1–31, 1989. [43] Q. Xie, Y. Li, G. Wang, and Y. Lian, “An unobtrusive system for heart rate monitoring based on ballistocardiogram using hilbert transform and viterbi decoding,” IEEE Journal on Emerging and Selected Topics in Circuits and Systems, vol. 9, no. 4, pp. 635–644, 2019. [44] Y.-C. Chang, “Physiological signal detection with automotive seat sensors,” Academic thesis, Department of Electrical Engineering, National Tsing Hua University, 2019. |